![Amazone EDX 9000-TC Operating Manual Download Page 144](http://html1.mh-extra.com/html/amazone/edx-9000-tc/edx-9000-tc_operating-manual_2919753144.webp)
Settings
144
EDX 9000-TC BAH0048-6 09.2019
8.2.2
Installing/removing the metering roller
CAUTION
Switch off the AMATRON 3 on-board computer before
working on the metering unit.
DANGER
Secure the tractor and implement against unintentional start-up
and rolling (see section 6.2, Seite 106)
The metering roller can be replaced more easily if the hopper is
empty.
Fit all the metering units on the implement with the same metering
roller. Open all shutters (Fig. 188/1) and secure [linch pin (Fig.
188/2)].
1. Remove the linch pin (Fig. 188/2).
(Only required with filled fertiliser hopper to
close the hopper with the shutter (Fig.
188/1).
2. Push the shutter (Fig. 188/3) into the
metering unit up to the stop.
The shutter seals the fertiliser hopper.
Fertiliser cannot pour out inadvertently
when the metering roller is being replaced.
Fig. 188
3. Loosen two nuts with the supplied tool (Fig.
189/1), but do not remove them.
Fig. 189