Cleaning, maintenance and repairs
EDX 9000-TC BAH0048-6 09.2019
203
What should be observed when cleaning with a high-pressure
cleaner/steam cleaner:
Do not clean any electrical components.
Do not clean any chromed components.
Never aim the cleaning jet from the cleaning nozzle of the high
pressure cleaner/steam jet directly on lubrication points,
bearings, rating plate, warning signs, and stickers.
Always maintain a minimum jet distance of 300 mm between the
high pressure cleaning or steam jet cleaning nozzle and the
implement.
The set pressure of the high-pressure cleaner/steam jet must
not exceed 120 bar.
Comply with safety regulations when working with high pressure
cleaners.
Completely dispose of fertiliser residue. Fertiliser residues
harden up and can damage rotating components on the next
use.
12.2.1 Daily fast cleaning of the singling unit and the spur gears
DANGER
Dressing dust is toxic and must not be inhaled or come into
contact with body parts.
When emptying the seed hopper and the singling unit or when
removing dressing dust, e.g. with compressed air, wear a protective
suit, face mask, safety glasses and gloves.
1. Secure the tractor against unintentional
start-up and rolling.
2. Open the bottom flap (Fig. 283/1).
The bottom flap is secured with quick-
release clamps (Fig. 283/2).
Fig. 283
Summary of Contents for EDX 9000-TC
Page 27: ...General Safety Instructions EDX 9000 TC BAH0048 6 09 2019 27 Fig 3 Fig 4...
Page 243: ...Hydraulic diagram EDX 9000 TC BAH0048 6 09 2019 243 Fig 346...
Page 244: ...Hydraulic diagram 244 EDX 9000 TC BAH0048 6 09 2019...
Page 245: ...Notes EDX 9000 TC BAH0048 6 09 2019 245 14 Notes Space for your notes...