![Altera PHY IP Core User Manual Download Page 24](http://html.mh-extra.com/html/altera/phy-ip-core/phy-ip-core_user-manual_2910918024.webp)
3–6
Chapter 3: 10GBASE-R PHY IP Core
Parameter Settings
Altera Transceiver PHY IP Core
March 2012
Altera Corporation
User Guide
Stratix V Devices
You specify the analog parameters for Stratix V devices using the Quartus II
Assignment Editor, the Pin Planner, or through the Quartus II Settings File (
.qsf
). The
default values for analog options fall into three categories:
■
Global
— These parameters have default values that are independent of other
parameter settings.
■
Computed
—These parameters have an initial default value that is recomputed
based on other parameter settings.
■
Proxy
—These parameters have default values that are place holders. The
Quartus II software selects these initial default values based on your design;
however, Altera recommends that you replace these defaults with values that
match your electrical board specification.
P
r
e-emphasis p
r
e-
t
ap se
tt
ing
0–7
Sets the amount of pre-emphasis on the TX buffer.
Inve
rt
t
he p
r
e-emphasis p
r
e-
t
ap
pola
r
i
t
y se
tt
ing
On
Off
Determines whether or not the pre-emphasis control signal for the
pre-tap is inverted. If you turn this option on, the pre-emphasis
control signal is inverted.
P
r
e-emphasis fi
r
s
t
pos
t
-
t
ap
se
tt
ing
0–15
Sets the amount of pre-emphasis for the 1st post-tap.
P
r
e-emphasis second pos
t
-
t
ap
se
tt
ing
0–7
Sets the amount of pre-emphasis for the 2nd post-tap.
Inve
rt
t
he p
r
e-emphasis second
pos
t
-
t
ap pola
r
i
t
y
On
Off
Determines whether or not the pre-emphasis control signal for the
second post-tap is inverted. If you turn this option on, the
pre-emphasis control signa is inverted.
Receive
r
common mode vol
t
age
T
r
i-S
t
a
t
e
0.82V
1.1v
Specifies the RX common mode voltage.
Receive
r
t
e
r
mina
t
ion
r
esis
t
ance
OCT_85_OHMS
OCT_100_OHMS
OCT_120_OHMS
OCT_150_OHMS
Indicates the value of the termination resistor for the receiver.
Receive
r
DC
0–4
Sets the equalization DC gain using one of the following settings:
■
0–0 dB
■
1–3 dB
■
2–6 dB
■
3–9 dB
■
4–12 dB
Receive
r
s
t
a
t
ic equalize
r
se
tt
ing:
0–15
This option sets the equalizer control settings. The equalizer uses a
pass band filter. Specifying a low value passes low frequencies.
Specifying a high value passes high frequencies.
Table 3–6. PMA Analog Options (Part 2 of 2)
Name
Value
Description