Chapter 4 Parameter Index
89
Function
code
Parameter
name
LCD display
Setting range
Factory
setting
Modif
ication
MODBU
S address
PE.02
Set
frequency
when the
latest fault
occurs
Set
frequency
when a fault
occurs
0~upper limit frequency
0.00Hz
*
0F02
PE.03
Output
current
when the
latest fault
occurs
Output
current
when a fault
occurs
0 ~ 2 times of the rated current
0.0A
*
0F03
PE.04
DC busbar
voltage
when the
latest fault
occurs
Bus voltage
when a fault
occurs
0~1000V
0V
*
0F04
PE.05
Service
condition
when the
latest fault
occurs
Service
condition
when a fault
occurs
0: StP Stop 1: Acc Acceleration 2:
dEc deceleration
3: con Constant speed
StP
*
0F05
PE.06
Fault history
(the latest)
Fault
history 1
The same with PE.00
NULL
*
0F06
PE.07
Fault history
2
Fault
history 2
The same with PE.00
NULL
*
0F07
PE.08
Fault history
3
Fault
history 3
The same with PE.00
NULL
*
0F08
PE.09
Accumulate
d running
time
Running
time
0~65530h
0h
*
0F09
PE.10
Cumulative
power-on
time
Power-on
time
0~65530h
0h
*
0F0A
PE.11
Total
electricity
consumption
(MWh)
Cumulative
electricity
consumptio
n (MWh)
0~9999MWh
0MWh
*
0F0B
PE.12
Total
electricity
consumption
(KWh)
Cumulative
electricity
consumptio
n (KWh)
0~999KWh
0KWh
*
0F0C