Chapter 5 Detailed Function Introductions
134
P5.10 Operating Timing T7
Setting range: 0.0~3600 [10.0]
P5.11 Operating Timing T8
Setting range: 0.0~3600 [10.0]
P5.12 Operating Timing T9
Setting range: 0.0~3600 [10.0]
P5.13 Operating Timing T10
Setting range: 0.0~3600 [10.0]
P5.14 Operating Timing T11
Setting range: 0.0~3600 [10.0]
P5.15 Operating Timing T12
Setting range: 0.0~3600 [10.0]
P5.16 Operating Timing T13
Setting range: 0.0~3600 [10.0]
P5.17 Operating Timing T14
Setting range: 0.0~3600 [10.0]
P5.18 Operating Timing T15
Setting range: 0.0~3600 [10.0]
Notes:
Define each stage of time during the programmable multi-stage speed operation, the run time varies from 0.0
to 3600 s (for example, if P5.03 is set to min, the unit is min), it is continuous and adjustable. When running
time is set to 0, the speed of this stage is skipped, the inverter will run at the speed of next stage.
P5.19 Step T1 program operating setting
Setting range: 1 F~4 r [1F]
P5.20 Step T2 program operating setting
Setting range: 1 F~4 r [1F]
P5.21 Step T3 program operating setting
Setting range: 1 F~4 r [1F]
P5.22 Step T4 program operating setting
Setting range: 1 F~4 r [1F]
P5.23 Step T5 program operating setting
Setting range: 1 F~4 r [1F]
P5.24 Step T6 program operating setting
Setting range: 1 F~4 r [1F]
P5.25 Step T7 program operating setting
Setting range: 1 F~4 r [1F]
P5.26 Step T8 program operating setting
Setting range: 1 F~4 r [1F]
P5.27 Step T9 program operating setting
Setting range: 1 F~4 r [1F]
P5.28 Step T10 program operating setting
Setting range: 1 F~4 r [1F]
P5.29 Step T11 program operating setting
Setting range: 1 F~4 r [1F]
P5.30 Step T12 program operating setting
Setting range: 1 F~4 r [1F]
P5.31 Step T13 program operating setting
Setting range: 1 F~4 r [1F]
P5.32 Step T14 program operating setting
Setting range: 1 F~4 r [1F]
P5.33 Step T15 program operating setting
Setting range: 1 F~4 r [1F]
Notes:
Specify the acceleration and deceleration time and the running direction of the inverter at each stage. There
are eight combinations with the meanings shown in Table 5-5-1.
Table 5-5-1 PLC program run setup description
Symbol
Acc/Dec time
Direction
1F
Acc/Dec time 1
P0.18.P0.19
F: Forward
1r
r: Reverse
2F
Acc/Dec time 2
P2.28, P2.29
F: Forward
2r
r: Reverse
3F
Acc/Dec time 3
P2.30, P2.31
F: Forward
3r
r: Reverse
4F
Acc/Dec time 4
P2.32, P2.33
F: Forward
4r
r: Reverse