Chapter 4 Parameter Index
64
This page is only for 35R5GB and above models
Functi
on
code
Parameter
LCD display
Setting range
Factor
y
setting
Mo
d.
MOD
BUS
addres
s
6: upper and lower limits of
wobble frequency
7: Inverter is in zero speed
operation
8: Simple PLC stage
operation completion
indication
9: PLC cycle completion
indication
10: Completion of readiness
for operation of inverter
(RDY)
11: Free stopping
12: Auto restart
13: Time reaching
14: Counting reaching output
15: Set running time reaching
16: Torque reaching detection
17: CL current-limit action
18: Overvoltage stall
19: Inverter failure
20: External fault stopping
(EXT)
21: Uu1 undervoltage
stopping
22: CE communication alarm
23: Overload detection signal
(OLP)
24: Abnormality of analog
signal 1
25: Abnormality of analog
signal 2
26: STEP Steps of program
running
(Valid for DO \ Y1 \ Y2 \
Y3, 26 is required to set)
27: Fault type output
(Valid for DO \ Y1 \ Y2,
27 is required to set)
(Continued on next page)
P3.23
reserve
reserve
0
×
0417
P3.24
Relay 1
(TA / TB / TC)
Output function
selection
Relay 1 output
(Contd.)
28: Cut-to-length reaching,
level signal
29: Sleeping
30: Zero speed
31: Zero servo state (reserve)
32: Reverse control signal
(reserve)
33: Actual direction of
rotation
thirty-four: Abnormality of
analog signal 3
35: Underload detection signal
19
×
0418
P3.25
Relay 2
(BRA/BRB/BRC)
Output function
selection
Relay 2 output
0
×
0419