60
HM 6Split
HM 12Split
Section 9 |
Control
Menu 5.11.1.1 - heat pump
Menu 5.10 - change log
Menu 5.11 - slave settings
Menu 5.11.1 - EB101 - 5.11.8 - EB108
Make settings for the installed slave here. To see
what settings you can make, see installation manual
for the relevant installed slave.
Read off any previous changes to the control system
here.
The date, time and ID no. (unique to certain settings)
and the new set value is shown for every change.
Settings for installed slaves can be made in the sub
menus.
Make settings for the installed slaves here.
IMPORTANT
The change log is saved at restart and remains un-
changed after factory setting.
Menu 5.11.1.2 - GP12 EB101
op. mode
Heating/cooling
Setting range: auto / intermittent
Factory setting: intermittent
speed during operation
heating, hot water, pool, cooling
Setting range: auto / manual
Factory setting:
auto
Set the operating mode for the charge pump here.
auto:
The charge pump runs according to the current
operating mode for the controller.
intermittent:
The charge pump starts and stops 20 sec-
onds before and after the compressor in the heat pump
Factory setting:
This menu allows setting the rotations with which
the GP12 circulating pump is to run in the current op-
erating mode. In "auto" mode, the speed of the feed
pump is adjusted automatically to ensure optimal op-
eration.
If "auto" is activated for heating operation, you can
also make the setting "max. allowed speed" which re-
stricts the charge pump and does not allow it to run
at a higher speed than the set value.
For manual operation of the charge pump deactivate
"auto" for the current operating mode and set the val-
ue to between 1 and 100 % (the previously set value
for "max. allowed speed" no longer applies).
In this menu, we can set the maximum and minimum
speeds of the circulation pump. The settings depend
on the central heating system.
Despite the entered settings for cooling mode, cool-
ing is not active. To activate cooling, see the section
"Cooling settings".
Factory setting:
5.12 - country
Select here where the product was installed. This al-
lows access to country specific settings in your product.
Language settings can be made regardless of this
selection.
IMPORTANT
This option locks after 24 hours, restart of display or
program updating.
CAUTION
Changes to settings in menu 5.11 can only be edited by
qualified personnel/service.