50
HM 6Split
HM 12Split
Section 9 |
Control
Menu 2.9 - Advanced
Menu 3 - INFO
Menu 3.1 - service info
Menu 3.2 - compressor info
Menu 3.3 - info. o podg. pom.
The advanced menu is intended for advanced users
only.
To prevent bacterial growth in the water heater, the
compressor and the immersion heater can increase
the hot water temperature for a short time at regular
intervals. More information after selecting "?".
The length of time between increases can be select-
ed here. The time can be set between 1 and 90 days.
Factory setting is 14 days. Tick/untick "activated" to
start/switch off the function.
Factory setting:
activated: on
period: 14 dni
start time: 00:00
The information menu is used to read information.
The status information of the menu is displayed to
the right of the menu.
Information about the heat pump’s actual operating sta-
tus (e.g. current temperatures etc.) can be obtained here.
No changes can be made. The information is on several
pages. Turn the control knob to scroll between the pages.
A QR code appears on one side. This QR code indicates
serial number, product name and limited operating data.
Information about the compressor’s operating status
and statistics can be obtained here. No changes can
be made. The information is on several pages. Turn
the control knob to scroll between the pages. More
information after selecting "?".
Information about the additional heat's settings, oper-
ating status and statistics can be obtained here. No
changes can be made. The information is on several
pages. Turn the control knob to scroll between the pag-
es. More information after selecting "?".
Menu 2.9.1 - Periodic increase