51
HM 6Split
HM 12Split
Section 9 |
Control
Menu 3.4 - alarm log
Menu 4 - MY SYSTEM
Menu 4.1 - plus functions
Menu 4.1.3 - internet
Menu 4.1.8 - smart energy source™
Menu 4.2 - op. mode
Menu 3.5 - indoor temp. log
To facilitate fault-finding the heat pump operating sta-
tus at alarm alerts is stored here. You can see infor-
mation for the 10 most recent alarms. To view the run
status in the event of an alarm, mark the alarm and
press the OK button.
This menu contains information about the work and
driver settings. Status information for the relevant menu
can be found on the display to the right of the menus.
Settings for any additional functions installed in HM
6Split / HM 12Split can be made in the sub menus.
Here you make settings for connecting HM 6Split /
HM 12Split to the internet. More information after se-
lecting "?".
The function prioritises how / to what extent each
docked energy source will be used. Here you can
choose if the system is to use the energy source
that is cheapest at the time. You can also choose if
the system is to use the energy source that is most
carbon neutral at the time. More information after se-
lecting "? ".
The heat pump operating mode is usually set to "auto".
It is also possible to set the heat pump to "add. heat
only", but only when an addition is used, or "manual" and
select yourself what functions are to be permitted.
Change the operating mode by marking the desired
mode and pressing the OK button. When an operating
mode is selected, it shows what is permitted in the heat
pump (crossed out = not permitted) and selectable al-
ternatives to the right. To select selectable functions
that are permitted or not, mark the function using the
control knob and press the OK button. More informa-
tion after selecting “?”.
Here you can see the average temperature indoors
week by week during the past year. The dotted line in-
dicates the annual average temperature.
The average outdoor temperature is only shown if a
room temperature sensor/room unit is installed.
To read off an average temperature
1. Turn the control knob so that the ring on the shaft
with the week number is marked.
2. Press the OK button.
3. Follow the grey line up to the graph and out to the
left to read off the average indoor temperature at
the selected week.
4. You can now select to take read outs for different
weeks by turning the control knob to the right or
left and read off the average temperature.
5. Press the OK or Back button to exit read off mode.
IMPORTANT
For these functions to work the network cable must
be connected.