Specifications
82
Goldeye G/CL Technical Manual V4.1.1
Operating conditions
Absolute quantum efficiency
Parameter
Values
Operating temperature
-20 °C to +55 °C (case)
Storage temperature
-30 °C to +70 °C (ambient)
Sensor cooling temperature,
setpoints **
+20 °C (default and calibrated)
+25 °C, +35 °C, +50 °C (other setpoints)
or user-confugurable
Relative humidity
10 % to 95 %, non-condensing
Power requirements (DC)
10.8 V to 30.0 V or via PoE
Max. power consumption
<12.95 W (@ PoE),
10.8 W (@ 12 VDC)
Typical power consumption
without cooling
6.5 W (@ PoE),
5 W (@ 12 VDC)
** Even though the first temperature setpoint is pre-configured to +20 °C, it is
possible to set it to a lower temperature. However, if the sensor temperature is
lower than the ambient temperature, especially in humid environments,
condensation may occur.
Table 48: G‐008 SWIR TEC1 ‐ Operating conditions
Figure 15: G‐008 SWIR TEC1 ‐ Absolute quantum efficiency