Triggering
165
Goldeye G/CL Technical Manual V4.1.1
Acquiring
Active during an acquisition stream.
LineIn1
Active when there is an external trigger at LineIn1.
LineIn2
Active when there is an external trigger at LineIn2.
Strobe1
The output signal is controlled according to Strobe1
settings.
CC1
(Camera Link only) active if trigger is detected on CC1.
The CC1 output acts the same way all other Goldeye
outputs do.
CC2
(Camera Link only) active if trigger is detected on CC2.
The CC2 output acts the same way all other Goldeye
outputs do.
CC3
(Camera Link only) active if trigger is detected on CC3.
The CC3 output acts the same way all other Goldeye
outputs do.
CC4
(Camera Link only) active if trigger is detected on CC4.
The CC4 output acts the same way all other Goldeye
outputs do.
Figure 53: Goldeye G/CL signals output block diagram
Source signal
Description
Table 116: Goldeye G/CL ‐ possible sources for output signals (sheet 2 of 2)
GPO
Acquisi
Ɵ
onTriggerReady
FrameTriggerReady
FrameTrigger
Exposing
FrameReadout
Acquiring
LineIn1
LineIn2
Strobe1
Read from
so
Ō
ware
Output
signal
Output mode
selectable
via so
Ō
ware
Opto-
coupler
Polarity
selectable
via so
Ō
ware
CC1
CC2
CC3