Triggering
161
Goldeye G/CL Technical Manual V4.1.1
Out 2 (pin 12) and Out 3 (pin 5) - opto-isolated
Out 2
and
Out 3
signals are optically isolated and require the user to provide a
voltage level at
Isolated Out Power
.
An example of the functional circuit is indicated in Table 50 on page 162.
The opto-isolated inputs can be connected directly to the system for voltages up to
24 VDC. An external resistor is not necessary.
Possible low output voltage
Output voltage may drop
down to 3.5 V
under full load.
Signal
Output
Possible voltage source OutV
CC
Range
3 V to 30 V
Maximum output current per output
20 mA
Table 113: Output 2 / Output 3 voltage source and current per channel
Possible low output voltage
Output voltage may drop
by 2.5 V
under full load.