Camera interfaces
149
Goldeye G/CL Technical Manual V4.1.1
Adjusting the gaps
Besides the Camera Link clock frequency, there are four parameters available that
can be used for timing control. These parameters affect the gaps between the FVAL
and LVAL signals.
Mono 8, Mono 12 (2 Taps)
Mono 14 (1Tap)
(ROI (W × H
)
25 MHz
40 MHz
25 MHZ
40 MHz
636 × 508 (full res.)
100
100
73
100
636 × 480
106
106
77
106
320 × 256
325
325
274
325
320 × 240
346
346
292
346
160 × 120
1015
1015
1015
1015
128 × 32
3507
3507
3507
3507
128 × 8
8264
8264
8264
8264
Table 102: Goldeye CL‐032 ‐ maximum achievable frame rates
Mono 8, Mono 12 (2 Taps)
Mono 14 (1Tap)
(ROI (W × H
)
25 MHz
55 MHz
85 MHz 25 MHz 55 MHz 85 MHz
640 × 512 (full res.)
125
276
301
68
151
234
640 × 480
134
295
321
73
161
250
320 × 256
428
251
909
251
553
855
320 × 240
456
268
968
268
590
912
160 × 120
1404
912
2557
912
2004
2557
128 × 32
5524
3802
9174
3802
8333
9174
128 × 8
17241
12658
25000
12658
25000
25000
Table 103: Goldeye CL‐033 ‐ maximum achievable frame rates
Figure 44: Principle of Camera Link data transfer
FVAL
LVAL
DVAL