Temperature control
191
Goldeye G/CL Technical Manual V4.1.1
The cooling power and heat dissipation capability of the Goldeye is limited.
Therefore, the temperature difference achievable by the TEC is limited as well.
Table 122 displays the maximum temperature difference, and the maximum power
necessary to achieve that.
TEC setpoints
Model
1
2
3
4
CL-008 TEC1
+20 °C
1
+25 °C (Default)
+35 °C
+50 °C
CL-008 Cool TEC1
-5 °C
+5 °C (Default)
+10 °C
+20 °C
CL-032 TEC1
+5 °C
+20 °C (Default)
+35 °C
+50 °C
CL-032 Cool TEC2
-20 °C (Default)
-5 °C
+10 °C
(n/a)
CL-033 TEC1
+5 °C
+20 °C (Default)
+35 °C
+50 °C
CL-033 TECless
(n/a)
(n/a)
(n/a)
(n/a)
G-008 TEC1
+20 °C
1
+25 °C (Default)
+35 °C
+50 °C
G-008 Cool TEC1
-5 °C
+5 °C (Default)
+10 °C
+20 °C
G-032 TEC1
+5 °C
+20 °C (Default)
+35 °C
+50 °C
G-032 Cool TEC2
-20 °C (Default)
-5 °C
+10 °C
(n/a)
G-033 TEC1
+5 °C
+20 °C (Default)
+35 °C
+50 °C
G-033 TECless
(n/a)
(n/a)
(n/a)
(n/a)
1
The first temperature setpoint may be set lower than +20 °C. However, if the
sensor temperature is lower than the ambient temperature, especially in humid
environments, condensation may occur.
Table 121: Defined temperature setpoints for Goldeye cameras
Model
Max. power consumption
for cooling
Min.
Δ
T
between case and FPA
CL-008 TEC1
< 5.5 W
20 K
CL-008 Cool TEC 1 < 5.5 W
30 K
CL-032 TEC1
< 5.5 W
30 K
CL-032 Cool TEC2
< 12 W
60 K
CL-033 TEC1
< 4 W
25 K
G-008 TEC1
< 5.5 W
20 K
G-008 Cool TEC1
< 5.5 W
30 K
Table 122: Cooling limits for Goldeye cameras (except TECless models)
(sheet 1 of 2)