Starting the acquisition automatically
To start the acquisition automatically after the camera powers up, follow the steps
lined out below:
Step 1:
Go to the
AcquisitionAutoStartMode
feature and set it to
On
.
Step 2:
Select a user set, using the
UserSetSelector
feature.
Step 3:
Save the current camera parameters in the selected user set, using the
UserSetSave
feature.
Step 4:
To set the selected user set as default user set that will be active after
the next start of the camera, activate it using the
UserSetLoad
feature.
Result:
Now the camera will start the acquisition automatically after the next
power-up.
Description
Length [clock cycles]
Min
Default
Max
A
Minimum gap between the rising edges of the
FVAL signal and the first line’s LVAL signal.
The real delay may be higher than the value
specified with this feature.
Feature name:
ClMinFvalToLvalDelay
0
32
1023
B
Width of the line gap.
Feature name:
ClLvalToLvalDelay
1
64
1024
C
Gap between the falling edges of the last lines’
LVAL signal and the FVAL signal.
Feature name:
ClLvalToFvalDelay
0
32
1024
D
Minimum gap from one falling edge to the next
rising edge of the FVAL signal.
The real value may be higher than the value
specified by this feature.
Feature name:
ClMinFvalToFvalDelay
1
32
1024