OK <value> = 0 to 3.
ERROR Otherwise.
M - Speaker Control
This command controls speaker on or off according to the supplied parameter.
Syntax
M[<value>]
Defined Values
<value> Decimal number corresponding to the selected option.
0 Speaker off.
1 Speaker on during call establishment, but off when
receiving carrier. (Default.)
2 Speaker on.
3 Speaker is off when receiving carrier and during
dialing, but on during answering.
Result Codes
OK <value> = 0 to 3.
ERROR Otherwise.
&G - Select Guard Tone
This command is included for compatibility only and has no effect other than returning an OK result lode
Syntax
&G[<value>]
Defined Values
<value> Decimal number corresponding to the selected option.
0 Included for compatibility only and has no effect
other than returning an OK result code. (Default.)
1 Included for compatibility only and has no effect
other than returning an OK result code.
2 Included for compatibility only and has no effect
other than returning an OK result code.
Result Code
OK <value> = 0 to 2.
ERROR Otherwise.
&P - Select Pulse Dial Make/Break Ratio
This command determines the make/break ratio used during pulse dialing. It is only effective
if the appropriate bit to enable this command is set through the .INF File. If enabled, it will
override the make/break ratios in the OEM parameters in the .INF File. The default is
country-dependent.
Syntax
&P[<value>]
Defined Values
<value> Decimal number corresponding to the selected information.
0 Selects 39%-61% make/break ratio at 10 pulses per second. (Default.)
1 Selects 33%-67% make/break ratio at 10 pulses per second.
2 Selects 39%-61% make/break ratio at 20 pulses per second.
3 Selects 33%-67% make/break ratio at 20 pulses per second.
Result Codes