Publication 0160-5.18 - June 2003
B-12
DeviceNet Information
Class Code 0x28 —
Motor Data Object
Instance 1 Attributes
Common Services
Class Attributes:
None Supported
Number of Instances:
1
Attribute ID
Access
Rule
Name Data
Type
Min/Max
Units
Default
Description
6
Get/Set
Rated Current
UINT
0 to 100.00
0.01 Amps
115% of
Drive Rating
Rated Stator Current
(from motor nameplate)
7
Get/Set
Rated Voltage
UINT
110 to 460
1 Volt
Drive Rating
Rated Base Voltage
(from motor nameplate)
9
Get/Set
RatedFreq
UINT
10 to 240
1 Hz
60 Hz
Rated Electrical Frequency
(from motor nameplate)
15
Get/Set
BaseSpeed
UINT
200 to 32000
1 RPM
1800
RPM
Nominal Speed at Rated Frequency
(from motor nameplate)
Service
Code
Implemented for:
Service
Name
Class
Instance
0x0E
No
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single