Publication 0160-5.18 - June 2003
Using 160-DN2 with DeviceNet Scanner
6-7
Enabling Network Control
The 160-DN2 module must be configured to accept commands from
the network. To do this, configure the drive “Input Mode” parameter
(
Configuring Drive Input Mode
1.
In the Current Value column, click on the value for
Parameter 46
- [Input Mode]
and select “Network Control” from the dropdown
list.
Important:
Remember to jumper or close drive Terminals 7 and
8 on TB2 before the drive can start.
2.
Click
Apply
to save the changes.
Figure 6.5
Network Control Screen
!
ATTENTION:
Changing this parameter value may
cause unpredictable network conditions, resulting in
equipment damage, personal injury, or death. Ensure
that you understand how changing this parameter
affects your application.