520
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Appendix A
CIP Objects
Table 274 - Transient Status
Bit
Description
Bit
Description
0
Transient buffer 0 status.
16
spare
1
17
2
18
3
19
4
Transient buffer 1 status.
20
5
21
6
22
7
23
8
Transient buffer 2 status.
24
9
25
10
26
11
27
12
Transient buffer 3 status.
28
13
29
14
30
15
31
Alarm Buffer Status Definition
0
Buffer Free
Buffer is available, ready for a transient event.
1
Data Ready Normal
Transient completed normally. Could be overwritten by a
new event.
2
Data Latched Normal
Transient completed normally. Buffer latched.
3
Transient in Progress RPM
Delta RPM acquisition in progress.
4
Transient in Progress Time
Delta time acquisition in progress.
5
Data Ready Aborted
Speed crossed back over the initiating threshold. Could be
overwritten by a new event.
6
Data Latched Aborted
Speed crossed back over the initiating threshold. Buffer
latched.
7
Data Ready Buffer Full
Buffer was filled before event concluded. Could be
overwritten by a new event.
8
Data Latched Buffer Full
Buffer was filled before event concluded. Buffer latched.
9
Buffer Not Allocated
Buffer not used.