Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
467
CIP Objects
Appendix A
Source of Speed Data
Any one of the following can be identified as the speed reference for Normal
CM data.
Waveform Record Length
Number of samples = 256 * (2^(Index))
FFT Resolution
Defines the FFT line resolution that is used for the Normal CM data FFT. For
Advanced CM data, additional line resolutions can be requested.
The Normal CM data object specifies the transient dynamic data, note
however that it is limited to a maximum of a 900 line FFT and 2048 point
TWF. Normal CM data can be set to higher lines/samples and this setting
reflects in Trend and Alarm data but stored Transient Data is 900 line FFT and
2048 point TWF).
Value
Description
0
Tacho/Speed 0
1
Tacho/Speed 1
Index
0
1
2
3
4
5
Samples
256
512
1024
2048
4096
8192
Index
TWF Samples
FFT Lines
Base FFT
Lines
(1)
(1) The Base FFT Lines represent the size of the raw processed FFT and are the number of lines returned if no adjustments are made
for decimation and filtering. Control of application of relevant factors for the applied decimation and filtering is provided in the
SpecialRequest member of the CM Record Request structure (
Decimation
None
Alternate
Path
(2)
(2)
Or if -60 dB filter is applied (Aeroderivative Measurement Type)
Primary
Path
(3)
(3) And the standard -24 dB/octave filter is applied.
4
4096
1600
1800
1000
600
3
2048
800
900
500
300
2
1024
400
450
250
150
1
512
200
225
125
75
0
256
100
112
67
32