308
Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Chapter 10
Operate the Module
Status Indicators
Main Module Status Indicators
The dynamic measurement module (1444-DYN04-01RA) includes 14 status
indicators. Twelve indicators are on the top of the module and one additional
status indicator on each of the Ethernet connectors.
provides descriptions of the meaning of the 12 status indicators on the
top of the main module.
Table 79 - DYN Module Status Indicators
Main Module Status Indicators
Status
Indicator
Description
OFF
Green
Blue
Red
Red/Green
Blue/Green
Solid
Flashing
(off)
Solid
Flashing
(off)
Solid
Flashing
(off)
Flashing
Flashing
PWR
Power status
6.5V power
not OK
6.5V power
OK
—
—
—
—
—
—
—
RUN
Aux
processor run
status
Powered off
or not
running
—
Application
running
O/S running
Configuratio
n activity
—
—
—
—
MS
Module
status
Powered off
Operational
No
configuration
—
During FW,
update
indicates
that update
is being
written to
memory
major fault,
not
recoverable
Duplicate IP
address
Firmware
Update in
process
—
NS
Network
status
No network
connection
Connected
No
connections
—
—
Duplicate IP
address
Connection
timeout
Firmware
Update in
process
—