4.1.2
Environment
4.1.2.1
Climatic Conditions
-
Operation
•
Temperature: for maximum reliability, it is recommended you comply with an ambient
temperature of between 5 and 40 degrees Celsius, with a maximum variation of 5
degrees Celsius per hour.
•
Humidity: the humidity must be in the range 10% - 80% (no condensation) with a
maximum variation of 10% per hour.
-
Storage
•
Temperature: the temperature must be kept between -20 and +70 degrees Celsius.
•
Humidity: the humidity must be kept in the range 10 - 95% (no condensation).
4.1.2.2
Vibration
No vibration, even intermittent, may be transmitted to the equipment when running.
4.1.2.3
Site
-
Choose a dry, clean and well ventilated location.
-
Maintain an ambient air flow to ensure normal ventilation. If the air flow is blocked or
restricted, of the incoming air is too hot, overheating is possible.
-
When installing the equipment in an enclosed 19" rack, verify that the rack is provided with
a fan suited to the heat dissipation of the equipment installed. Maintain a minimum gap of 3
cm around the side ventilation holes (left and right sides), and of 10 cm minimum around
the ventilation holes at the rear of the equipment. Verify that the air flow is not impeded on
the sides of the rack.
-
When fixing the system directly to the wall using the wall-mounting kit (OmniPCX Office
RCE Small and OmniPCX Office RCE Medium platforms only), maintain a free space of at
least 15 cm around the whole system. Ensure that no objects are placed on the upper part
of the system to restrict the extraction of hot air. When installing several platforms, it is
preferable to align then horizontally. When superposing them vertically, they should be
separated by at least 10 cm.
-
Verify that the cables connecting the Alcatel-Lucent OmniPCX Office Communication
Server or other equipment, or the supports for the housing structure (19" rack for example)
do not obstruct the air flow through the platform.
-
A switchable 230 V or 110 V mains socket (according to country) - 50Hz (LNE) is required
at less than 1 m from the platform unless it is installed in a rack in which case the
integrated circuit breaker is used.
-
Adequate lighting must be provided.
4.2
Connections and Cabling
4.2.1
Detailed description
4.2.1.1
Output Connectors
( )
4-3
Summary of Contents for OmniPCX Office
Page 1: ...Installation Manual Release 9 0 October 2012 ...
Page 8: ... P 8 6 Q 8 7 R 8 7 S 8 8 T 8 8 U 8 9 V 8 9 W 8 9 0 6 ...
Page 14: ...Chapter 1 1 6 ...
Page 19: ...2 3 Installation 2 3 1 Overview ___change begin___ 2 5 ...
Page 48: ...Chapter 3 3 18 ...
Page 176: ...Chapter 4 4 128 ...
Page 178: ...Figure 5 1 Virtual Key Functions for Operator Sets in KeySystem mode Chapter 5 5 2 ...
Page 179: ...Figure 5 2 Virtual Key Functions for Manager Assistant Normal sets in KeySystem Mode 5 3 ...
Page 181: ...Figure 5 4 Virtual and Physical Add on Key Functions for Attendant Sets in KeySystem mode 5 5 ...
Page 182: ...Figure 5 5 US only Virtual Key Functions for Operator Sets in KeySystem Mode Chapter 5 5 6 ...
Page 183: ...Figure 5 6 US only Virtual Key Functions for Manager Assistant Sets in KeySystem Mode 5 7 ...
Page 184: ...Figure 5 7 US only Virtual Key Functions for Normal Sets in KeySystem Mode Chapter 5 5 8 ...
Page 185: ...Figure 5 8 Virtual Key Functions for Operator Manager Assistant Normal Sets in PABX Mode 5 9 ...
Page 186: ...Figure 5 9 US only Virtual Key Functions for Operator Sets in PABX Mode Chapter 5 5 10 ...
Page 187: ...Figure 5 10 US only Virtual Key Functions for Manager Assistant Sets in PABX Mode 5 11 ...
Page 190: ...Chapter 5 5 14 ...
Page 213: ...settings are overwritten when configured PBXs are added to a network 6 23 ...
Page 214: ...Chapter 6 6 24 ...
Page 220: ...Chapter 7 7 6 ...