7.1
Maintenance Level 1
7.1.1
Maintenance
This module provides maintenance advice on different hardware components of the
Alcatel-Lucent OmniPCX Office Communication Server system.
7.1.1.1
Battery Maintenance
Alcatel-Lucent OmniPCX Office Communication Server systems (except the OmniPCX Office
RCE Compact) are supplied with internal batteries that provide back-up power in the event of a
mains power failure. Alternatively, all systems may be optionally equipped with an external
battery pack to provide back-up power.
To guarantee system shutdown without data loss in the event of a mains power failure or if the
mains plug is unplugged from the wall socket, replace the batteries every two years. This
maintenance operation is vital to guarantee sufficient power autonomy to allow the files to be
saved before the system shuts down.
Before replacing batteries, the system must be powered down and the power cable removed
from the mains supply.
-
To replace internal batteries, the rear panel of the system cabinet must be removed and
the battery drawer pulled out.
-
To replace external batteries, the external battery box must be opened.
To maintain a good balance, replace all the batteries at the same time with
batteries of the same type, from the same manufacturer and from the same batch.
Make sure you respect the correct polarities when replacing batteries. There is a
risk of explosion if the batteries are incorrectly replaced. Used batteries must be
disposed of according to the battery manufacturer's instructions.
The batteries are supplied uncharged. File saving in the event of a power failure can only be
guaranteed once the batteries have been charged; that is, about 12 hours after turning on the
system (PowerCPU switch in ON position).
7.1.1.1.1 Internal Battery Characteristics
-
number: 1 (OmniPCX Office RCE Small), 2 in parallel (OmniPCX Office RCE Medium) or 3
in series (OmniPCX Office RCE Large)
-
sealed lead battery
-
1,2 Ah / 12 V
-
fire resistance better than or equal to UL94-V2
7.1.1.1.2 External Battery Characteristics
-
number: up to 2 for OmniPCX Office RCE Compact, up to 3 for OmniPCX Office RCE
Small and OmniPCX Office RCE Medium platforms, up to 6 for OmniPCX Office RCE
"
7-1
Summary of Contents for OmniPCX Office
Page 1: ...Installation Manual Release 9 0 October 2012 ...
Page 8: ... P 8 6 Q 8 7 R 8 7 S 8 8 T 8 8 U 8 9 V 8 9 W 8 9 0 6 ...
Page 14: ...Chapter 1 1 6 ...
Page 19: ...2 3 Installation 2 3 1 Overview ___change begin___ 2 5 ...
Page 48: ...Chapter 3 3 18 ...
Page 176: ...Chapter 4 4 128 ...
Page 178: ...Figure 5 1 Virtual Key Functions for Operator Sets in KeySystem mode Chapter 5 5 2 ...
Page 179: ...Figure 5 2 Virtual Key Functions for Manager Assistant Normal sets in KeySystem Mode 5 3 ...
Page 181: ...Figure 5 4 Virtual and Physical Add on Key Functions for Attendant Sets in KeySystem mode 5 5 ...
Page 182: ...Figure 5 5 US only Virtual Key Functions for Operator Sets in KeySystem Mode Chapter 5 5 6 ...
Page 183: ...Figure 5 6 US only Virtual Key Functions for Manager Assistant Sets in KeySystem Mode 5 7 ...
Page 184: ...Figure 5 7 US only Virtual Key Functions for Normal Sets in KeySystem Mode Chapter 5 5 8 ...
Page 185: ...Figure 5 8 Virtual Key Functions for Operator Manager Assistant Normal Sets in PABX Mode 5 9 ...
Page 186: ...Figure 5 9 US only Virtual Key Functions for Operator Sets in PABX Mode Chapter 5 5 10 ...
Page 187: ...Figure 5 10 US only Virtual Key Functions for Manager Assistant Sets in PABX Mode 5 11 ...
Page 190: ...Chapter 5 5 14 ...
Page 213: ...settings are overwritten when configured PBXs are added to a network 6 23 ...
Page 214: ...Chapter 6 6 24 ...
Page 220: ...Chapter 7 7 6 ...