VC-12 Near-end severely ES threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
VC12NSEScTHR24
Information
The VC-12 near-end severely errored seconds counter exceeded the provisioned
threshold during a 24-hour monitoring period.
Alarm category
Quality of service (performance monitoring)
ASAP
sdhLOPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
Possible causes are:
•
Dirty optical connector(s).
•
Equipment fault(s) in the upstream station.
Actions
Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
1-232
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007
Summary of Contents for 1643 AM
Page 346: ......