Remote Power Supply Open Circuit
...................................................................................................................................................................................................................................
Alarm identifier
RPScOPENC
Information
No electric current is flowing through the electrical circuit in the remote power
supply box, connected to the SRU.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
–
Cause
This can be caused by a blown fuse, faulty wiring, or missing components in
the remote power supply box or even by manually disconnecting the power
box.
Actions
Identify and repair the defective component in the power box.
Alarm messages
...................................................................................................................................................................................................................................
1-124
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007