2 Mbit/s extension board failure - protected
...................................................................................................................................................................................................................................
Alarm identifier
E12XcEQF
Information
The 2 Mbit/s extension board is defective.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
The red “Fault” LED is lit.
Cause
The on board self-test circuitry indicates that an essential function of the unit
fails.
Actions
Replace the 2 Mbit/s extension board.
Note(s)
As 1643 AM and 1643 AMS systems do not support hardware protection,
E12XcEQF, and E12XcUPF are always reported simultaneously as a reminder
that a hardware failure is service affecting.