VC-12 Remote defect indicator
...................................................................................................................................................................................................................................
Alarm identifier
VC12cRDI
Information
A Remote Defect Indication (RDI) is being received.
Alarm category
Transmission
ASAP
sdhLOPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
The downstream far end station of the network element that reported the alarm
detects a malfunction at its receive side: VC-12 Excessive error rate, VC-12
Path signal label mismatch, or tributary unit alarm indication signal received.
Actions
No alarms in the reporting network element. React on the far-end alarms.
Follow the clearing actions for those alarm(s).
Alarm messages
...................................................................................................................................................................................................................................
1-238