WAN Dropped packets threshold crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier
WANDPcTHR15
Information
The counter for the number of dropped packets at the WAN side exceeded the
provisioned threshold during a 15-minutemonitoring period.
Alarm category
Quality of service (performance monitoring)
ASAP
ethPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
Possible causes are:
•
Dirty optical connector(s)
•
Equipment fault(s) in the upstream station.
Actions
Check upstream external cabling or equipment.
Note(s)
The counter only includes packets dropped due to errors. It does not include
packets dropped due to congestion.