Maximum number of VLAN instances exceeded in MIB
...................................................................................................................................................................................................................................
Alarm identifier
MIBcVLANOVFW
Information
The maximum number of VLAN instances that can be stored in the
management information base (MIB) has been exceeded.
Alarm category
Transmission
ASAP
ethPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications
The red fault LED is lit.
Cause
Too many VLAN instances per network element or too many VLAN/port
associations have been created.
Actions
Remove unused VLAN instances and re-plan the network to decrease the
number of VLAN instances.
Note(s)
A maximum number of 1024 VLAN instances per network element is
supported.
A maximum number of 2000 VLAN/port associations is supported.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-83