Pluggable Module failure - protected
...................................................................................................................................................................................................................................
Alarm identifier
PMcEQF
Information
The respective pluggable module failed.
Alarm category
Equipment
ASAP
equipment
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
The red fault LED associated to the failed pluggable module is lit.
Cause
Hardware failure of the pluggable module.
Actions
Replace the failed module.
Note(s)
As no equipment protection exists for pluggable modules, PMcEQF, and
PMcUPF are always reported simultaneously as a reminder that a pluggable
module failure is service affecting.