SDSL Loss of frame alignment
...................................................................................................................................................................................................................................
Alarm identifier
SDSLcLOF
Information
Alignment to the frame structure of the SHDSL signal, received at a
customer-side SHDSL port of the LTU, is not possible.
Alarm category
Transmission
ASAP
sdsl
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
–
Cause
The “Loss of sync word” (LOSW) condition has been detected at the respective
customer-side SHDSL port of the LTU. This means that the SHDSL segment
between the respective customer-side SHDSL port of the LTU and the next
attached SHDSL device has failed.
Actions
For the failed SHDSL segment:
•
Verify the correct routing of interconnecting cables.
•
Verify that the connectors are properly connected at the local and remote
end of the SHDSL segment.
•
Verify that the receiver at the local end of the SHDSL segment (i.e. at the
LTU where the LOSW condition has been detected) functions properly.
•
Verify that the transmitter at the remote end of the SHDSL segment (i.e. at
the next attached SHDSL device) functions properly.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-127