STM-4 MS Remote defect indicator
...................................................................................................................................................................................................................................
Alarm identifier
MS4cRDI
Information
The STM-4 receive signal contains MS- RDI.
Alarm category
Transmission
ASAP
sdhMS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
The downstream equipment has detected a receive signal failure, and has
inserted MS-RDI as a consequent action.
Actions
Locally no actions can be taken. Analyze the alarm state of the downstream
equipment and take appropriate measures.
Note(s)
The downstream equipment has detected one of the following failure conditions
at its receive side:
•
STM-4 MS AIS (Multiplex Section Alarm Indication Signal)
•
STM-4 LOS (Loss Of Signal) or
•
STM-4 LOF (Loss Of Frame).
This is reported to the transmitting equipment via the Remote Defect Indication
(RDI) which is used to draw local attention to the remote failure.
Alarm messages
...................................................................................................................................................................................................................................
1-198
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007