P12s Near-end errored seconds threshold crossing 15-min
egress
...................................................................................................................................................................................................................................
Alarm identifier
P12SNESgcTHR15
Information
The P12s near-end errored seconds counter exceeded the provisioned threshold
during a 15-minutes monitoring period (SDH -> PDH).
Alarm category
Quality of service (performance monitoring)
ASAP
pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Cause
Equipment fault(s) in the upstream station.
Actions
Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................