The 

  are digital panel  meters  for connection of measurement for voltage (10 V) and current 

(1 mA, 20 mA or 4 ... 20 mA) with 4 ranges.

Operation: 

The setting of measuring range and display range is made by positioning DIP switches. The chosen input range is 
user adjustable from 10% to 100 % of the full scale value by potentiometer on the rear of the meter.

Further 

BETA 90A

 versions from the series:

BETA 90A

 F

           

Technical data

Display

Display range 
Decimal point position 
Negative display indication 

“-”

Digit height 

8 mm / 7-segment digits

Overload indication

last 3 digits blank

Measuring range

Direct voltage 

0 ... 10 V 
(input current < 100 u

A)

Direct current

0 ... 1 mA; 0 ... 20 mA; 4 ... 20 mA
(Voltage drop < 200 mV)

Range adjustment 

1 : 10 

Accuracy 

 < 0.2 % of range + 1 digit

Temperature coefficient 

100 ppm / °C, plus

Zero point drift

 

  

200 ppm / °C

Supply of power

Direct voltage DC

Environmental conditions             

Climatic class 

Class 2 to VDE / DIN 3540 

Operating temperature 

0 ... 50 °C

Storage temperature

-40 °C ... +80 °C 

Safety class

II to IEC 348/VDE 0411

Protections class

IP 20 to IEC EN 60 529

Front

IP 54 (IP 65 on request)

Device safety 

correspond IEC EN 61 010

EMC immunity 

correspond DIN EN 61 000-4-1 to 4

EMC radiated interference

  

correspond DIN EN 50 081 class B 

Dimensions and weights              

Bezel size 

48 mm x 24 mm to DIN 43 718

Panel cut-out 

45 

+0.6 mm

 x 22.2 

+0.3 mm

Overall depth

69 mm 

Weight

  

45 g approx

Sundry

Connections

Plug-in screw

BETA 90A

Voltage measurement, 4 ranges.

1999 
selectable

48 V DC (  10 % )

1.2 W, isolated

21 ... 30 V DC

1.2 W, isolated

12 V DC (   10 % )

1.2 W, isolated

 

±

±