Summary of Contents for 22-812

Page 1: ...ance and frequency It s ideally suited for field lab shop and home applications You can a so connect the meter to your computer and use the supplied software to log and graph measurements Please read...

Page 2: ...lacing the Fuses 8 Basic Operation and Features 9 Testing the Display 9 Using the Stand 9 Connecting Test Leads 9 Using Power Lock 9 Using Monitor 10 Range Selection 10 Taking Measurements 11 Taking R...

Page 3: ...equired before measuring If you do not have this protection DO NOT MEASURE THESE CIRCUITS To reduce the risk of fire or shock hazard do not expose this product to rain or moisture For indoor use only...

Page 4: ...ARNING THE GUARD PROTECTS AGAINST ELECTRIC SHOCK DO NOT REMOVE IT 10A MAX FUSED Plug the red lead into this jack to measure current higher than 400 mA RadioShack 6 SELECT Press to toggle measurement o...

Page 5: ...Operation and Features For the most accurate reading the temperature should be between 65 and 83 F 18 and 28 C with a maximum of 75 relative humidity Testing the Display To test the meter s display t...

Page 6: ...00V DC dddd V 10A dd dd A 40 nF dd dd nF 750VAC 400n ddd d n 400 nF ddd d nF 4kn d ddd kn 4 F d ddd F 400 A ddd d A 40kn dd dd kn 40 F dd dd F RadioShack 10 Taking Measurements Taking Relative Measure...

Page 7: ...aximum input limit for AC DC current measurement is 1OA If you do not know the amount of current in the circuit you are measuring always connect the red test lead to 1 OA MAX RadioShack 12 1 Taking Me...

Page 8: ...e meter s buzzer does not sound if the circuit resistance is greater than about 50 ohms meaning the circuit is not continuous RadioShack 14 Taking Measurements Checking Diodes You can check diodes tra...

Page 9: ...function press Hz DUTY WIDTH until Hz kHz or MHz appears 3 To select the duty cycle or pulse width function press Hz DUTY WIDTH until appears to select duty cycle or until S or mS appears to select p...

Page 10: ...er s serial port The supplied cable fits only one way Do not force it Configuring and Using the Meter and Software After connecting you must configure your meter and the Meter View software so that th...

Page 11: ...l scale except 4 0nF range f_rom 0 SnF to full scale PULSE WIDTHS Frequency Range 10Hz to 100kHz 1 S to 90mS at 5 0V square wave 5 of Reading 2 in Last Digit RadioShack 20 Specifications K TEMPERATURE...

Page 12: ...380 Counts Low Battery Indication 6 3V 0 3 V Sleep Mode Current 10 A Normal 20 A Max Input Impedance DCV ACV 10Mohm Power Source One 9V battery not supplied Operating Temperature 41 to 104 F 5 to 40 C...

Page 13: ...ons check with your local RadioShack store RadioShack Customer Relations 300 RadioShack Circle Fort Worth TX 76102 04 04 www radioshack com 0 Protect the environment by recycling used electronics Go t...

Reviews: