background image

 

 
 

ArtNet-DMX Mux24 

 

 
 

User Manual 

 
 
 

 

 
 
 
 

 

 

Art-Net™ Designed by and Copyright Artistic Licence Holdings Ltd.

 

 

 

Summary of Contents for DMX4ALL ArtNet-DMX Mux24

Page 1: ...ArtNet DMX Mux24 User Manual Art Net Designed by and Copyright Artistic Licence Holdings Ltd ...

Page 2: ...le Each input is individually configurable Both the function Mode as well as the DMX Channels to be controlled are adjustable for each input 4 configurable Timer 4 separately configurable Timer allow time controlled on off switching of DMX Channels Easy Configuration A user friendly configuration via a web browser allows quick and easy setting of all parameters No special software is required a no...

Page 3: ...Distance Digital Input 8x Analog Input or Long Distance Digital Input Modes Switch Button ON Button OFF Button ON OFF Dimmer UP Dimmer DOWN Dimmer UP DOWN Button ON Dimmer UP Button OFF Dimmer DOWN Button ON OFF Dimmer UP DOWN Analog 0 10V Analog 0 5V Analog 1 10V Timer 4x adjustable Timer Dimensions 99mm x 82mm ...

Page 4: ...n ArtNet DMX Mux24 Ethernet GND V IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16 GND GND GND DMX DMX POWER 12 24V DC DMX OUT 5V IN17 IN18 IN19 IN20 IN21 IN22 IN23 IN24 Analog 0 10V Analog 0 5V Analog 1 10V ...

Page 5: ...ccurs via a web interface which can be called up via any web browser Set the IP with the IP Configurator The IP Configurator allows setting the IP Address and the net mask also if the PCs network setting is not in the IP Range of the ArtNet DMX Mux24 Install the programm IP Configurator Connect the ArtNet DMX Mux24 with the net mask and turn it on Start the programm IP Configurator The ArtNet DMX ...

Page 6: ... which will be used for the web interface as well as for the ArtNet Set your computers network card to this IP range to access the IP address via the web browser The PCs network settings must be the IP Address 2 0 0 1 and the subnet mask must be 255 0 0 0 Please take further details from the ArtNet Specifications ...

Page 7: ... an own IP Address that the assignment occurs clearly within the network Please use in accordance to the ArtNet Specification the IP Address 2 x x x or 10 x x x with the net mask 255 0 0 0 Any other IP Address can be used too like e g 192 168 1 10 In this case the net mask must be adjusted to 255 255 255 0 For a better distinction you can name the ArtNet DMX Mux24 anyway The short name is limited ...

Page 8: ...ast activates the ArtNet Data output to all ArtNet Devices The Dest IP will not be considered in this case Net SubNet Port Universe are the according ArtNet parameters Send only on change suppressed the regular repeated output of the values via ArtNet Factory defaults The Factory Settings will be restored with entering the number 7319 SAVE stores the configuration respectively restored the Factory...

Page 9: ...wiring occurs with a switch or a button connect to GND as shown in the following outline IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16 GND GND The inputs can be configured via the web interface Therefore the both configuration sides Input 1 8 and Input 9 6 are available Per Input the Mode and Channels which should be controlled can be entered here ...

Page 10: ... ON Button ON Channels will be turned on 100 Button OFF Button OFF Channels will be turned off 0 Button ON OFF Button ON OFF Channels will be switched between on and off 0 100 Dimmer UP Dimmer UP Channels will be dimmed upwards 0 100 Dimmer DOWN Dimmer DOWN Channels will be dimmed downwards 100 0 Dimmer UP DOWN Dimmer UP DOWN Channels will be dimmed upwards downwards change of direction after each...

Page 11: ...eeds than a VALUE So for the specified channels the value will be added A possible configuration for a 8Bit binary input is as follows Input IN1 up to IN8 Output DMX channel 1 Configuration INPUT1 Mode Switch Channel 1 1 INPUT2 Mode Switch Channel 1 2 INPUT3 Mode Switch Channel 1 4 INPUT4 Mode Switch Channel 1 8 INPUT5 Mode Switch Channel 1 16 INPUT6 Mode Switch Channel 1 32 INPUT7 Mode Switch Cha...

Page 12: ... for using as LONG DISTANCE digital inputs or analog inputs The inputs will be configured via the web interface The selection if the inputs should be used analog or digital occurs in the Global SETUP On the configuration site Input 17 24 the function of the single channels will be determined ...

Page 13: ...IN21 IN22 IN23 IN24 analog 0 10V analog 0 10V Connection with potentiometer GND V GND DMX DMX 5V IN17 IN18 IN19 IN20 IN21 IN22 IN23 IN24 10k 10k Connection as digital input The wiring as LONG DISTANCE digital input occurs with a switch or button connect to GND as shown in the following picture GND V GND DMX DMX 5V IN17 IN18 IN19 IN20 IN21 IN22 IN23 IN24 ...

Page 14: ...d via the timer so the single values must be entered separately with a comma For example a single channel with 100 or several channels with 100 110 120 Furthermore it is possible to specify to be outputted In this case the channel specifications need an Value e g 100 222 to set channel 100 to 222 If no value is specified 255 100 is outputted the specified value must be in the range 0 to 255 With S...

Page 15: ... IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16 GND GND GND DMX DMX DMX OUT 5V IN17 IN18 IN19 IN20 IN21 IN22 IN23 IN24 At the DMX Output a DMX Signal with 512 DMX Channels will be outputted The values of the DMX channels will be determined via the digital inputs and the configuration The configuration must occur via the web interface ...

Page 16: ... button Push button again and hold The green and yellow LED flashes now for ca 10 seconds alternately Release button meanwhile Now the Reset is in progress and the LEDs flashes 3x simultaneously as confirmation Alternatively you can restore the delivery status via the web browser Open Global Settings into web browser Enter the code 7319 within the input field under Factory Defaults Click Save Then...

Page 17: ...e list Click Firmware Update Select Firmware file bin and confirm Please wait until the Update has finished If an error occurs during the update you can start from the beginning any time Alternatively you can activate the Firmware Update via the web browser Open the Update into the web browser Enter the displayed code 1379 into the input field and click Send Start the Update Software DMX4ALL LAN U...

Page 18: ...ArtNet DMX Mux24 18 Equipment Top hat rail housing 1050 Power supply 12V 20W Network cable ...

Page 19: ...s necessary Initiation risk For the installation of the board the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installed systems components could as well as hidden defects ...

Page 20: ...tems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences which decrease go back to incorrect data This document does not contain assured characteri...

Reviews: