P12s Near- end unavailable seconds threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
P12SNUAScTHR24
Information
The P12s near-end unavailable seconds counter exceeded the provisioned
threshold during a 24-hour monitoring period (PDH -> SDH).
Alarm category
Quality of service (performance monitoring)
ASAP
pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
The alarm was generated because of a fiber cut or equipment fault(s) in the
upstream station.
Actions
Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-107