background image

SAFETY INFORMATION

The following safety information must be observed to insure
maximum personal safety during the operation of this meter:

1. Do not use the meter if the meter or test leads look damaged,

or if you suspect that the meter is not operating properly.

2. This meter is not recommended for high voltage industrial

use; for example, not for measurements of 440VAC or
600VAC industrial power mains.  The unit is intended for
use with low energy circuits to 1000VDC or 750VAC or high
energy circuits to 250VAC or DC.  Accidental misuse by
connection across a high voltage, high energy power source
when the meter is set up for mA measurement may be very
hazardous.

3. Turn off power to the circuit under test before cutting,

unsoldering, or breaking the circuit.  Small amounts of
current can be dangerous.

4. Use caution when working above 60VDC or 30VAC rms.

Such voltages pose a shock hazard.

5. When using the probes, keep your fingers behind the finger

guards on the probes.

6. Measuring voltage which exceeds the limits of the

multimeter may damage the meter and expose the operator
to a shock hazard.  Always recognize the meter voltage
limits as stated on the front of the meter.

SPECIFICATIONS

Display: 3 3/4 digit liquid crystal display (LCD) with a

maximum reading of 3999.

Polarity: Automatic, positive implied, negative polarity

indication.

Overrange: (OL) or (–OL) is displayed.
Zero: Automatic.
Low Battery Indication: The “       ” is displayed when the

battery voltage drops below the
operating level.

Measurement Rate: 2.5 times per second, nominal.
Operating Environment: 0

O

C to 50

O

C at <70% relative

humidity.

Storage Temperature: –20

O

C to 60

O

C, 0 to 80% R.H. with

battery removed from meter.

Accuracy: Stated accuracy at 23

O

C +5

O

C, <75% relative

humidity.

Power: Single standard 9-volt battery, NEDA 1604, JIS 006P,

IEC 6F22.

Battery Life: 150 hours typical with carbon-zinc.
Dimensions: 200mm (H) x 90mm (W) x 40mm (D).
Weight: Approx. 14 oz. (400g.) including battery.
Accessories: One pair test leads, one spare fuse (installed), 9V

battery (installed) and operating instructions.

+

DC VOLTS

Ranges: 400mV, 4V, 40V, 400V, 1000V
Resolution: 100

m

V

Accuracy: +(0.5% rdg + 1 dgt)
Input Impedance: 10M

W

Overload Protection: 1000VDC or 750VAC rms

AC VOLTS  

(50Hz - 500Hz)

Ranges: 400mV, 4V, 40V, 400V, 750V
Resolution: 100

m

V

Accuracy: +(1.5% rdg + 4 dgts) on 400mV to 400V ranges

+(2.0% rdg + 4 dgts) on 750V ranges

Input Impedance: 10M

W

Overload Protection: 1000VDC or 750VAC rms

DC CURRENT

Ranges: 40mA, 400mA, 10A
Accuracy: +(1.5% rdg + 1 dgt) on mA range

+(3.0% rdg + 1 dgt) on 10A range

Input Protection: 0.5A / 250V fast blow fuse

10A / 600V fast blow ceramic fuse

AC CURRENT  

(50Hz - 500Hz)

Ranges: 40mA, 400mA, 10A
Accuracy: +(2.0% rdg + 4 dgts) on mA range

+(3.5% rdg + 4 dgts) on 10A range

Input Protection: 0.5A / 250V fast blow fuse

10A / 600V fast blow ceramic fuse

RESISTANCE

Ranges: 400

W

, 4k

W

, 40k

W

, 400k

W

, 4M

W

, 40M

W

, 4000M

W

Accuracy: +(1.0% rdg + 4 dgts) on 400

W

range

+(0.8% rdg + 2 dgts) on 4k

W

to 4M

W

ranges

+(3.0% rdg + 4 dgts) on 40M

W

range

+[(5.0% rdg + 10 dgts) + 10 dgts] on 4000M

W

range

Open Circuit Volts: 0.6VDC (3.0VDC on 400

W

and

4000M

W

ranges)

Overload Protection: 500VDC or AC rms

CONTINUITY

Audible Indication: Less than 40

W

+20

W

Overload Protection: 500VDC or AC rms

DIODE TEST

Test Current: 1.0mA +0.6mA
Accuracy: +(3.0% rdg + 3dgt)
Open Circuit Volts: 3.0VDC typical
Overload Protection: 500VDC or AC rms

CAPACITANCE

Ranges: 4nF, 40nF, 400nF, 4

m

F, 200

m

F

Accuracy: +(5.0% rdg + 10dgts) on all ranges

+(8.0% rdg + 10dgts) above 100

m

F

Test Frequency: 200Hz

OPERATING INSTRUCTIONS

ELENCO LCM-1950

DIGITAL MULTIMETER