7
Suburban DynaLine Owner's Manual 04/2021 Rev.4
SLOPE DOWN TO THE OUTSIDE
1"
4
SURFACE OF FINISHED
FLOOR OR TOP OF CARPET
MIN. (PROJECTION BEYOND WALL)
1"
4
3 (MIN.)
1"
2
CABINET FRONT
WALL SLEEVE
2 (MIN.) SUPPORTS
(BY INSTALLER)
WALL SLEEVE ANGLES & SCREWS
(BY INSTALLER.)
DO NOT PUT HOLES THROUGH OR DRIVE
SCREWS INTO WALL SLEEVE BOTTOM!
REAR GRILLE
CAULK AROUND WALL SLEEVE
WINDOW OR WALL
(MAX.) LONG SCREWS FOR SECURING
ANGLES TO TOP & SIDES OF SLEEVE.
2
1"
WINDOW, CURTAIN WALL, OR WALL PANEL INSTALLATION
WINDOW, CURTAIN WALL, OR WALL PANEL INSTALLATION
Figure 9
CAUTION
Do not drill holes in bottom of sleeve. Bottom angle is for support only and is to be secured to wall.
4.
Secure wall sleeve to wall as illustrated in Figures 4 or 5. Be sure wall case is level (side to side-parallel to floor) and sloped 1/4”
from front to rear.
Do not put holes in bottom of sleeve, water damage to wall and floor will occur.
5.
Caulk around wall sleeve between the sleeve and building to form a weather tight seal against rain and snow.
Use only weather
proof caulking.
(See Figures 4 or 5)
6.
Seal around sleeve between finished interior wall and sleeve to minimize heat/cooling loss around sleeve. Seal may be caulking,
or if preferred, installer may trim around sleeve with molding or other suitable materials.
IMPORTANT: Installation of the rear grille must be made prior to installing the chassis as it secures from inside the wall
sleeve.
7.
Slide unit into wall sleeve and secure it to sleeve using the four #10 x 1/2 screws provided.
8.
Connect gas and electrical supply. Refer to Figure 10 for centerline location of gas connection and electrical connection when unit
is installed into wall sleeve.
NOTE
: This unit is factory set for 230 volt operation. If you wish to operate unit on 208 volts, the rocker switch located behind the
cabinet front on the controls panel
(see Figure 18)
must be switched to 208 volts.
NOTE
: On occasions, the voltage on a 230 volt model may drop. If the voltage drop is at or below 208 volts, the switch should be
switched to 208 volts.
9.
The operation of this unit is controlled by a built-in thermostat. A digital temperature read out will be displayed on the control panel.
For remote thermostat operation, connect the thermostat wiring to the terminal block located on the module board. Move switch #1
on the thermostat switch to “on”. (See Figure 11)
To reset controls, turn power off then back on.
NOTE
: Connecting remote thermostat overrides the built-in thermostat and you will not get a digital read out on the control panel.
There is no need to disconnect the built-in thermostat as shipped from factory.
10.
Reinstall air filter.
11.
The outlet air grille can be installed in either of two positions. The unit is delivered for horizontal air flow. If vertical air flow is desired,
remove grille and reinstall in alternate position. (See figure 12)
12.
Reinstall cabinet front. Do not operate unit with cabinet front removed.
CENTER LINE LOCATION FOR REAR GAS
CONNECTION
CENTER LINE LOCATION FOR
ELECTRICAL CONNECTION ON
UNIT WHEN INSTALLED INTO
WALL SLEEVE
WALL SLEEVE (OUTLINE)
UNIT (OUTLINE)
CENTER LINE LOCATION FOR FRONT GAS CONNECTION
WHEN INSTALLED INTO WALL SLEEVE
FRONT SURFACE
OF WALL SLEEVE
7 3/4"
5 5/8"
1 9/16"
5"
2 9/64"
TOP VIEW
S
ID
E
V
IEW
1/4"
Figure 10
Figure 11