23
Suburban DynaLine Owner's Manual 04/2021 Rev.4
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of
life. Refer to the installation instructions and/or owners manual provided with this appliance. Installation and service must
be performed by a qualified installer, service agency or the gas supplier.
WARNING
Installation of this appliance must be made in accordance with the written instructions provided in the manual. No agent,
representative or employee of Airxcel, Inc. - Suburban Division or other person has the authority to change, modify or waive any
provision of the instructions contained in the manual or this instruction sheet.
340547
L2
L1
COMPRESSOR
CONTACT
COMPRESSOR
L1
10
5
COMPRESSOR
RELAY
8
1
HI-LIMIT
2
11
PRESSURE
7
4
CONDENSOR
MOTOR
TEMP. SENSE
LO
HI
AIR
MOTOR
ROOM
POWER
EMERGENCY
IGNIT
OR
12
3
EXHAUST
MOTOR
24V.
230V.
VALVE
6
9
FLAME PROBE
ROCKER SWITCH
208V.
230V.
SW.
FLUE LIMIT
G
DE-ICER
SWITCH
PRESSURE
CONTROLLER
SWITCH N.C.
C
S
BR
Y
R
Y
COMPRESSOR
MOTOR
BR
ROOM AIR
BR
BK
EXHAUST
MOTOR
BK
BK
MOTOR
BR
BR
2
4
3
1
IGNITOR
10
11
12
7
8
9
4
5
6
1
2
3
TR
ANSFORMER
24V
230V
1
L
TERM.
BLOCK
L 2
BK
BK
R
PRESSURE
HI LIMIT
SW. N.C.
SW. N.O.
O
TEMP. SENSE
BK
BK
W
W
Y
Y
BK
BK
W
W
BK
BL
Y
BK
Y
R
R
R
R
BR
O
BR
BK
BK
208/230 V.A.C. WIRING DIAGRAM
340546
COMPRESSOR
RELAY
Y
Y
L2
R
BK
L1
WHITE
YELLOW
BROWN
BLACK
RED
BLUE
ORANGE
COLOR
R
W
Y
BR
BL
BK
CODE
O
FLAME
CONDENSER
BK
BL
MODULE
BOARD
(BUILT-IN T-STAT)
PROBE
O
DE-ICER
SW.
R
R
R
BK
R
BK
NOTE: ALL WIRES ARE 18 A.W.G. UNLESS
OTHERWISE SPECIFIED.
MAXIMUM RATING OF SUPPLY CIRCUIT
PROTECTIVE DEVICE 15 AMPS.
IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH
THE APPLIANCE MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105°C WIRE OR TYPE 150°C
WIRE WHERE SPECIFIED OR ITS EQUIVALENT.
105°C THERMOPLATIC 14 A.W.G. WIRE
TGS 200°C 18GA STRANDED TEFLON COATED
ROCKER
SWITCH
R
BL
O
N.C.
FLUE LIMIT
R
HIGH LOW
L1
COMB
COND
BLWR
FLAME
DOWN
PWR
FAN
MED
BK
BK
Y
R
G
PRESSURE
CONTROLLER
BK
SW. N.C.
G
VALVE
1
2
3
4
O
BR
Wiring Diagrams for
DYNALINE
230 Volt MODELS
with all-numeric serial numbers (up through 2015)
DYNA07AC • DYNA09AC • DYNA12AC • DYNA16AC
L2
L1
COMPRESSOR
CONTACT
COMPRESSOR
L1
10
5
COMPRESSOR
RELAY
8
1
HI-LIMIT
2
11
PRESSURE
7
4
CONDENSOR
MOTOR
TEMP. SENSE
LO
HI
AIR
MOTOR
ROOM
POWER
EMERGENCY
IGNIT
OR
12
3
EXHAUST
MOTOR
120V.
277V.
VALVE
6
9
FLAME PROBE
SW.
FLUE LIMIT
COMB. MTR
RELAY
24V.
277V.
LO FAN MTR
RELAY
HI FAN
MTR RELAY
G
PRESSURE
SW. N.C.
DE-ICER
SWITCH
340549
C
S
BR
Y
R
Y
COMPRESSOR
MOTOR
BR
ROOM AIR
BR
BK
EXHAUST
MOTOR
BK
MOTOR
BR
BR
2
4
3
1
IGNITOR
10
11
12
7
8
9
4
5
6
1
2
3
TR
ANSFORMER
24V
1
L
TERM.
BLOCK
L 2
BK
BK
R
PRESSURE
HI LIMIT
SW. N.C.
SW. N.O.
VALVE
O
TEMP. SENSE
BK
BK
W
W
Y
Y
BK
W
W
BL
Y
BK
Y
R
R
R
R
BR
O
BR
BK
BK
COMPRESSOR
RELAY
Y
Y
L2
R
BK
L1
WHITE
YELLOW
BROWN
BLACK
RED
BLUE
ORANGE
COLOR
R
W
Y
BR
BL
BK
CODE
O
FLAME
CONDENSER
BK
BL
MODULE
BOARD
O
BR
1
2
3
4
(BUILT-IN T-STAT)
PROBE
O
DE-ICER
SW.
R
R
BK
NOTE: ALL WIRES ARE 18 A.W.G. UNLESS
OTHERWISE SPECIFIED.
MAXIMUM RATING OF SUPPLY CIRCUIT
PROTECTIVE DEVICE 15 AMPS.
IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH
THE APPLIANCE MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105°C WIRE OR TYPE 150°C
WIRE WHERE SPECIFIED OR ITS EQUIVALENT.
105°C THERMOPLATIC 14 A.W.G. WIRE
TGS 200°C 18GA STRANDED TEFLON COATED
BR
N.C.
FLUE LIMIT
R
HIGH LOW
L1
COMB
COND
BLWR
FLAME
DOWN
PWR
FAN
MED
BK
BK
Y
R
277 VOL
T
277 V.A.C. WIRING DIAGRAM
TR
ANSFORMER
120V
277 VOL
T
R
BK
2
4
3
1
2
4
3
1
2
4
3
1
HI SPEED
RELAY
LO SPEED
RELAY
EXH MOTOR
RELAY
Y
Y
BR
BR
BR
O
BK
R
R
R
BK
R
BK
BK
G
O
BK
PRESSURE
SW. N.C.
340548
BK
BK
Wiring Diagrams for
DYNALINE
277 Volt MODELS
with all-numeric serial numbers (up through 2015)
DYNA12AC-7