Suburban DynaLine Owner's Manual 04/2021 Rev.4
4
16
42
4
1"
4
1" MIN.
MIN.
HEADER
(STEEL LINTEL IN BRICK CONSTRUCTION)
SURFACE OF FINISHED FLOOR
WALL SLEEVE FRAMING DIMENSIONS
REAR GAS HOOK-UP
WALL SLEEVE FRAMING DIMENSIONS
REAR GAS HOOK-UP
Figure 2
WALL SLEEVE FRAMING DIMENSIONS
FRONT GAS HOOK-UP
Figure 3
NOTE: UNITS APPROVED FOR 0" CLEARANCE TO COMBUSTIBLE CONSTUCTIONS TOP, SIDES, AND BOTTOM. FRONT AND REAR CLEARANCE
NOT APPLICABLE AS THERE CAN BE NO CONSTRUCTION COMBUSTIBLE OR NON-COMBUSTIBLE TO THE FRONT OR REAR OF THE OPENING.
WALL SLEEVE FRAMING DIMENSIONS
FRONT GAS HOOK-UP
16
42
4
1"
4
1" MIN.
MIN.
HEADER
(STEEL LINTEL IN BRICK CONSTRUCTION)
FINISHED FLOOR
3 2
1" MIN.
SUB-FLOOR
NOTE:
UNITS APPROVED FOR 0" CLEARANCE TO COMBUSTIBLE CONSTRUCTIONS TOP, SIDES, AND BOTTOM. FRONT AND REAR CLEARANCE NOT
APPLICABLE AS THERE CAN BE NO CONSTRUCTION COMBUSTIBLE OR NON-COMBUSTIBLE TO THE FRONT OR REAR OF THE OPENING.
5.
The installer should allow for drywall or other interior wall finishes when locating sleeve during rough-in. (See Figures 4 or 5)
6.
Prior to installing the wall sleeve, one must consider the method to be used to drain the condensate from the wall sleeve. Two
methods may be used:
a.
Free Drain (External)- A general acceptable alternative where the condensate drains from the wall sleeve through three
exterior drain holes and drops to open ground. (See Figure 6). The condenser fan is designed to pick up normal condensate
and evaporate it off the condenser coil.
b.
Drain Kit - A condensate drain kit is recommended for positive drainage when specified or code requires or when condensate is
heavy under conditions of extreme humidity for extended periods of time. The drain tube assemblies may be installed externally
on rear flange of the wall sleeve or underneath the wall sleeve to the external side of building. (See Figure 7). The condensate
can be freely drained to ground level or routed in tubing to a disposable location. Drain tube kits are designed for 1/2” O.D.
copper tubing.
NOTE:
Excessive rain water entering the unit through the outside grille may not be entirely removed during operation of the unit.
Excessive rain water will drain through the raised weep holes provided on the rear of the wall sleeve.
7
. After selecting a location for wall sleeve, inspect the wall and floor areas to determine that there are no hidden electrical wires,
propane or other flammable gas-liquid piping or tubing, ducts, girders or wall studs that will interfere with the proper installation and
safe operation of the unit or the proper installation of gas supply lines and electrical service
8.
The cabinet front is shipped with the unit chassis. Side flanges on chassis are secured to sleeve from inside room to insure proper
security and mounting.
SLOPE DOWN TO THE OUTSIDE
1"
4
SURFACE OF FINISHED
FLOOR OR TOP OF CARPET
1 MIN. (PROJECTION BEYOND EXTERIOR WALL)
5"
8
Y"
X"
MOUNTING HOLES AND SCREWS
(BY INSTALLER.)
DO NOT PUT HOLES THROUGH
WALL SLEEVE BOTTOM!
REAR GRILLE
CAULK AROUND WALL SLEEVE
SURFACE OF FINISHED EXTERIOR WALL
Y" = 14 - ( X" + 1 )
3"
4
8
5"
SURFACE OF FINISHED INTERIOR WALL
CABINET FRONT
X" REPRESENTS EITHER THE
DIMENSION REQUIRED TO FLUSH
SLEEVE TO FINISHED TRIM OR
MOLDING, OR THE DISTANCE
SLEEVE PROJECTS INTO ROOM
BEYOND FINISHED INTERIOR
WALL.
NOTE: X" CAN BE 0" IF
SLEEVE IS FLUSH WITH
FINISHED INTERIOR WALL.
WALL INSTALLATION
REAR GAS HOOKUP
WALL INSTALLATION REAR GAS HOOK-UP
Figure 4