120
Appendix B - Tables
Table
Number
Page
Number Description
Section I - Product Description, Specifications & Dimensional Data
Table 1A
5
Specifications
Table 1B
5
Dimensions (See Figures 1A, 1B, 1C and 1D)
Table 2
10
Ratings
Section III - Pre-Installation and Boiler Mounting
Table 3
13
Apex Boiler Model Stacking Combinations
Section IV - Venting
Table 4
16
Vent/Combustion Air System Options
Table 5
16
Vent/Combustion Air Pipe Length – Two-Pipe Direct Vent System Options
CPVC/PVC
Polypropylene (PP) or Polypropylene (PP)/PVC
Stainless Steel/PVC or Galvanized Steel)
Table 6A
17
Vent System and Combustion Air System Components Equivalent Length vs. Component Nominal
Diameter
Table 6B
18
Vent Combustion Air Equivalent Length Calculation Work sheet
Table 7A
21
CPVC/PVC Vent & Air Intake Components Included With Boiler
Table 7B
21
CPVC/PVC Vent & Air Intake Components (Installer Provided) required for Optional Horizontal
(Snorkel) Termination
Table 7C
22
CPVC/PVC Vent & Air Intake Components (Installer Provided) required for Optional Vertical (Roof)
Termination
Table 8
24
Expansion Loop Lengths
Table 9
26
Listed Polypropylene Vent System Manufacturers
Table 10A
27
Listed Polypropylene Pipe, Fittings and Terminations - M&G/DuraVent
Table 10B
27
Listed Polypropylene Pipe, Fittings and Terminations - Centrotherm Eco
Table 11A
30
Thermal Solutions Vent System Components (Stainless Steel)
Table 11B
30
Alternate Vent Systems and Vent Components (Stainless Steel)
Section VI - Water Piping and Trim
Table 11C
35
Maximum Condensate Flow
Table 12
41
Flow Range Requirement Through Boiler
Table 13A
42
Recommended Taco Circulators for 50 ft. Equivalent ft. Near Boiler Piping [Approximately 20 ft.
Straight Pipe, (4) 90° Elbows, and (2) Full Port Ball Valves]
Table 13B
42
Recommended Grundfos Circulators for 50 Equivalent ft. Near Boiler Piping [Approximately 20 ft.
Straight Pipe, (4) 90° Elbows, and (2) Full Port Ball Valves]
Table 14
43
Fitting & Valve Equivalent Length
Table 15
47
Multiple Boiler Water Manifold Sizing
Section VII - Gas Piping
Table 16A
51
Maximum Capacity of Schedule 40 Black Pipe in CFH* (Natural Gas) For Gas Pressures of 13.8
in. w.c. or Less
Table 16B
52
Maximum Capacity of Schedule 40 Black Pipe in CFH* (LP Gas) For Gas Pressures of 0.5 psig or
Less
Table 17
52
Equivalent Length of Standard Pipe Fittings & Valves
Table 18
53
Specific Gravity Correction Factors
Table 19
53
Min./Max. Pressure Ratings
Summary of Contents for APEX
Page 57: ...57 VIII Electrical continued Figure 26 Ladder Diagram ...
Page 58: ...58 VIII Electrical continued ...
Page 59: ...59 Figure 27 Wiring Connections Diagram VIII Electrical continued ...
Page 105: ...105 ...
Page 109: ...109 XIII Repair Parts continued APX625 APX725 and APX825 APX825 shown ...
Page 112: ...112 XIII Repair Parts continued APX425 and APX525 ...
Page 114: ...114 XIII Repair Parts continued APX625 APX725 and APX825 ...
Page 122: ...122 ...
Page 123: ...123 ...