3
1
Meter and adjust selection keys
Select the output voltage and current of any one
supply (+6V, +25V, or -25V output) to be monitored on the display and allow knob
adjustment of that supply.
2
Tracking enable / disable key
Enables / disables the track mode of
±
25V supplies.
3
Display limit key
Shows the voltage and current limit values on the display and
allows knob adjustment for setting limit values.
4
Recall operating state key
Recalls a previously stored operating state from
location “1”, “2”, or “3”.
5
Store operating state / Local key
1
Stores an operating state in location “1”, “2”,
or “3” / or returns the power supply to local mode from remote interface mode.
6
Error / Calibrate key
2
Displays error codes generated during operations, self-test
and calibration / or enables calibration mode (the power supply must be
unsecured
before performing calibration).
7
I/O Configuration / Secure key
3
Configures the power supply for remote
interfaces / or secure and unsecure the power supply for calibration.
8
Output On/Off key
Enables or disables all three power supply outputs. This key
toggles between two states.
9
Control knob
Increases or decreases the value of the blinking digit by turning
clockwise or counter clockwise.
10
Resolution selection keys
Move the flashing digit to the right or left.
11
Voltage/current adjust selection key
Selects the knob function to voltage control or
current control.
1
The key can be used as the “Local” key when the power supply is in the remote
interface mode.
2
You can enable the “calibration mode” by holding down this key when you
turn on the power supply.
3
You can use it as the “Secure” or “Unsecure” key when the power supply is
in the calibration mode.
Summary of Contents for E3631-90002
Page 9: ...8...
Page 14: ...1 1 General Information...
Page 25: ...24...
Page 26: ...2 2 Initial Operation...
Page 34: ...3 3 Front Panel Operation...
Page 64: ...4 4 Remote Interface Reference...
Page 113: ...112...
Page 114: ...5 5 Error Messages...
Page 124: ...6 6 Application Programs...
Page 137: ...136...
Page 138: ...7 7 Tutorial...
Page 153: ...152...
Page 154: ...8 8 Specifications...
Page 161: ...160...