Programming Resolution
+6V Output
+25V Output
-25V Output
Voltage
0.5 mV
1.5 mV
1.5 mV
Current
0.5 mA
0.1 mA
0.1 mA
Readback Resolution
+6V Output
+25V Output
-25V Output
Voltage
0.5 mV
1.5 mV
1.5 mV
Current
0.5 mA
0.1 mA
0.1 mA
Meter Resolution
+6V Output
+25V Output
-25V Output
Voltage
1 mV
10 mV
10 mV
Current
1 mA
1 mA
1 mA
Transient Response Time
Less than 50
m
sec for output recover to within 15 mV following a change in output
current from full load to half load or vice versa
Command Processing Time
Programming Commands : Maximum time for output to change after receipt of
APPLy and SOURce commands) : <50 msec
Readback Command : Maximum time to readback output by MEASure? command :
<100 msec
The Other Commands : < 50 msec
Tracking Accuracy
The ±25V outputs track each other within ±(0.2% of 20 mV).