![Agilent Technologies Agilent 33500 Series User Manual Download Page 182](http://html.mh-extra.com/html/agilent-technologies/agilent-33500-series/agilent-33500-series_user-manual_2867489182.webp)
181
Chapter 3 Features and Functions
Remote Interface Configuration
3
IP Address (LAN)
You can enter a static IP address for the 33500
Series as a four-byte integer expressed in
dot notation
(“nnn.nnn.nnn.nnn”, where “nnn” in each case is a byte value from 0 to
255). Each byte is expressed as a decimal value, with no leading zeros
(for example,
169.254.2.20
).
• If DHCP is on, it will attempt to assign an IP address to the
instrument. If it fails, AutoIP will attempt to assign an IP address to
the instrument.
• Contact your network administrator for a valid IP address to use for
your waveform generator.
• Enter the IP address using the numeric keypad or knob.
• The IP address is stored in
non-volatile
memory and does not change
when power has been off or after a remote interface reset.
•
Front panel operation:
Press
and press the
I/O Config
softkey.
Then press
LAN Settings
and
Modify Settings
. Finally, toggle the
first softkey to read
Manual
and press
IP Address
to enter a new IP
address.
• Enter the desired address.
•
Remote interface operation:
SYSTem:COMMunicate:LAN:IPADdress <
address
>
SYSTem:COMMunicate:LAN:IPADdress?
More About Dot Notation:
Dot-notation addresses (“nnn.nnn.nnn.nnn” where “nnn"
is a byte value) must be expressed with care, as most web software on the PC will
interpret byte values with leading zeros as octal numbers. For example,
"192.168.020.011" is actually equivalent to decimal "192.168.16.9" not
"192.168.20.11" because ".020" is interpreted as "16" expressed in octal, and ".011"
as "9". To avoid confusion, use only decimal expressions of byte values (0 to 255),
with no leading zeros.
For example, the 33500 Series assumes that all dot-notation addresses are
expressed as decimal byte values and strips all leading zeros from these byte values.
Thus, attempting to set an IP address of "192.168.020.011" will become
"192.168.20.11" (a purely decimal expression). Be sure to enter the exact
expression, "192.168.20.11", in your PC web software to address the instrument. Do
not use "192.168.020.011" - the PC will interpret this address differently due to the
leading zeros.
Summary of Contents for Agilent 33500 Series
Page 13: ...12 ...
Page 16: ...1 1 Quick Start ...
Page 41: ...40 Chapter 1 Quick Start To Rack Mount the Waveform Generator 1 ...
Page 42: ...2 2 Front Panel Menu Operation ...
Page 90: ...3 3 Features and Functions ...
Page 218: ...4 4 Application Programs ...
Page 243: ...242 Chapter 4 Application Programs Program Listings 4 ...
Page 244: ...5 5 Tutorial ...
Page 261: ...260 Chapter 5 Tutorial Ground Loops 5 ...
Page 262: ...6 Specifications ...