![Agilent Technologies Agilent 33500 Series User Manual Download Page 156](http://html.mh-extra.com/html/agilent-technologies/agilent-33500-series/agilent-33500-series_user-manual_2867489156.webp)
155
Chapter 3 Features and Functions
Burst Mode
3
Waveform Frequency
The
waveform frequency
defines the signal frequency during the burst in
the triggered and external gated modes. In the
triggered mode
, the
number of cycles specified by the
burst count
is output at the waveform
frequency. In the
external gated mode
, the waveform frequency is output
when the external gate signal is true.
Keep in mind that the waveform frequency is different than the “burst
period” which specifies the interval between bursts (triggered mode only).
• Waveform frequency: 1
Hz to 30 MHz (limited to 200 kHz for
ramps).
The default waveform frequency is 1 kHz
. (For an
internally
triggered
burst waveform, the minimum frequency is 126
Hz.) You
can select a sine, square, triangle, ramp, pulse, or arbitrary waveform
(noise is allowed only in the gated burst mode and DC is not allowed).
• Front-Panel Operation
: To set the waveform frequency, press the
Freq
softkey for the selected function. Then use the knob or numeric
keypad to enter the desired frequency.
• Remote Interface Operation
:
[SOURce[1|2]:]FREQuency {<
frequency
>|MINimum|MAXimum}
You can also use the
APPLy
command to select the function, frequency,
amplitude, and offset with a single command.
Summary of Contents for Agilent 33500 Series
Page 13: ...12 ...
Page 16: ...1 1 Quick Start ...
Page 41: ...40 Chapter 1 Quick Start To Rack Mount the Waveform Generator 1 ...
Page 42: ...2 2 Front Panel Menu Operation ...
Page 90: ...3 3 Features and Functions ...
Page 218: ...4 4 Application Programs ...
Page 243: ...242 Chapter 4 Application Programs Program Listings 4 ...
Page 244: ...5 5 Tutorial ...
Page 261: ...260 Chapter 5 Tutorial Ground Loops 5 ...
Page 262: ...6 Specifications ...