![Agilent Technologies Agilent 33500 Series User Manual Download Page 164](http://html.mh-extra.com/html/agilent-technologies/agilent-33500-series/agilent-33500-series_user-manual_2867489164.webp)
163
Chapter 3 Features and Functions
Triggering
3
External Triggering
In the external trigger mode, the waveform
generator will accept a hardware trigger applied to the rear-panel
Trig In
connector. The waveform generator initiates one sweep or
outputs one burst each time
Ext Trig
receives a TTL pulse with the
specified edge.
See also “Trigger Input Signal,” on the following page.
•
Front-Panel Operation
: The external trigger mode is like the manual
trigger mode except that you apply the trigger to the
Ext Trig
connector. To select the external source, press
and then
Trg Src
and
Ext
.
To specify whether the waveform generator triggers on the rising or
falling edge, press the
Trigger Setup
softkey and select the desired
edge direction by pressing
Slope
.
•
Remote Interface Operation
:
TRIGger:SOURce EXTernal
Use the following command to specify whether the waveform
generator triggers on the rising or falling edge.
TRIGger:SLOPe {POSitive|NEGative}
Summary of Contents for Agilent 33500 Series
Page 13: ...12 ...
Page 16: ...1 1 Quick Start ...
Page 41: ...40 Chapter 1 Quick Start To Rack Mount the Waveform Generator 1 ...
Page 42: ...2 2 Front Panel Menu Operation ...
Page 90: ...3 3 Features and Functions ...
Page 218: ...4 4 Application Programs ...
Page 243: ...242 Chapter 4 Application Programs Program Listings 4 ...
Page 244: ...5 5 Tutorial ...
Page 261: ...260 Chapter 5 Tutorial Ground Loops 5 ...
Page 262: ...6 Specifications ...