Front
P
anel
6.
Analyzer
Input
T
erminals
R,
A,
and
B
These
are
input
terminals
through
which
the
4395A
receives
signals
output
from
the
RF
OUT
terminal
and
then
fed
through
the
test
circuit.
How
to
use
these
input
terminals
diers
depending
on
which
analyzer
mode
you
use:
In
network
analyzer
mode
,
use
the
A
and
B
terminals
to
receive
signals
output
from
the
RF
OUT
terminal
and
then
fed
through
the
device
under
test
(DUT),
and
use
the
R
terminal
to
directly
feed
back
the
signal
output
from
the
RF
OUT
terminal
to
provide
the
reference
input
signal.
Y
ou
may
want
to
use
a
power
splitter
to
split
the
RF
OUT
signal
among
the
input
terminals
.
In
spectrum
analyzer
mode
,
you
can
use
any
of
these
three
terminals
to
monitor
the
spectrum
of
the
input
signals
.
In
impedance
analyzer
mode
,
which
is
available
with
option
010,
use
the
R
and
A
terminals
to
monitor
the
voltage
and
current
across
the
DUT
being
fed
with
the
signals
output
from
the
RF
OUT
terminal.
These
terminals
comply
with
INST
ALLA
TION
CA
TEGORY
I
of
IEC
1010-1.
Note
Do
not
exceed
the
operating
input
power
,
voltage
,
and
current
level
and
signal
type
appropriate
for
the
instrument
being
used,
refer
to
your
instrument's
operation
manual.
Note
Electrostatic
discharge(ESD)
can
damage
the
highly
sensitive
microcircuits
in
your
instrument.
ESD
damage
is
most
likely
to
occur
as
the
test
xtures
are
being
connected
or
disconnected.
Protect
them
from
ESD
damage
by
wearing
a
grounding
strap
that
provides
a
high
resistance
path
to
ground.
Alternatively
,
ground
yourself
to
discharge
any
static
charge
built-up
by
touching
the
outer
shell
of
any
grounded
instrument
chassis
before
touching
the
test
port
connectors
.
7.
RF
OUT
Connector
Connects
the
RF
output
signal
from
the
analyzer's
internal
source
to
a
test
set
or
power
splitter
.
The
output
impedance
at
this
connector
is
50
.
Note
that,
in
spectrum
analyzer
mode
,
the
RF
output
is
disabled
by
default.
When
you
perform
zero
span
measurement
in
spectrum
analyzer
mode
,
you
can
turn
the
RF
output
on.
8.
DC
SOURCE
(DC
V
oltage/Current
Output)
Connector
(Option
001)
This
connector
,
located
on
the
front
panel,
supplies
up
to
640
V
/
6100
mA
of
DC
voltage/current.
4-4
Front
and
Rear
Panels
Summary of Contents for 4395A
Page 8: ......
Page 9: ......
Page 10: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 16: ......
Page 50: ......
Page 58: ...Power Requirements Figure 2 1 Power Cable Supplied 2 6 Installation Guide ...
Page 69: ...Connecting an Active Probe Figure 2 10 Connecting Test Fixture Installation Guide 2 17 ...
Page 72: ......
Page 93: ...Step 2 Setting Up the 4395A Quick Start Guide 3 21 ...
Page 130: ......
Page 144: ......
Page 154: ......
Page 251: ...Measuring Zero Span Figure 8 28 Marker Time Analyzing the Measurement Results 8 49 ...
Page 262: ......
Page 278: ......
Page 376: ......
Page 410: ...Markers Figure A 19 Bandwidth Search Example A 34 Basic Measurement Theory ...
Page 448: ......
Page 449: ...B Softkey Reference Softkey Reference B 1 ...
Page 462: ...4Bw Avg5 B 14 Softkey Reference ...
Page 528: ......
Page 532: ......
Page 560: ......