A self diagnostic continuously checks all the system sensors.
If a sensor signal is not received for 5 or more seconds, the system will show a message that helps the operator to
identify the faulty sensor.
When an error message appears, you can no longer use the system. The only action you can do is enter into the
USER MENU by keeping the button pressed.
ALARMS - SENSORS
[troubleshooting]
Alarms - Sensors
ALARMS
BOOM 1
BOOM 2
When there
’
s a sensor alarm, all the
red LEDs are flashing.
ALARM
SCREEN
LED
ACTIVITY
CAUSE / SOLUTION
SENSOR “N”
blinking
WRONG SLOT ASSIGNED WITH SENSOR ASSIGNMENT
Check received sensors on previous “Sensors Check” page.
Do Sensor Assignment procedure
SENSOR “N”
(new system or new
components – usually
after start-up).
OFF
SENSOR NOT SYNCHRONIZED – WRONG CONFIGURATION
Do Sensor Assignment Procedure
If you can’t find the sensor in sensor assignment mode (sensor horizontal and REMOTE DISPLAY in
programming mode): charge battery.
SENSOR “N”
(during normal
operation).
OFF
SENSOR NOT SYNCHRONIZED – OUT OF RANGE
Move booms closer to the cab to make the re-synchronization faster.
Position the REMOTE DISPLAY in a better place to improve the radio range. Radio antenna is on the top
of the REMOTE DISPLAY.
Activity (synchronization) green LED inside the top-right part of the sensor.
You can see this LED flashing about once per second if the sensor is connected to the
REMOTE DISPLAY.