- 33 -
EZDigPro
User & Calibration Manual
[automatic calibration]
Dog Bone
EZCalibration
DogBone
Take Point 1
Press Enter
EZCalibration
DogBone
Take Point 1
Press Enter
Calibration
Done!
Calibration
Done!
Other sensors The dipper stick sensor (and - if you need 4 sensors – the articulated boom sensor) must be attached in
their final positions during the Dog Bone calibration procedure and shouldn’t be moved afterwards. If the dipper stick
sensor (or the articulated boom sensor) gets moved after the Dog Bone calibration, the calibration has to be done again!
Dog Bone
Boom 1 sensor
can be moved
again on Boom 1
Press Enter
Boom 1 sensor
can be moved
again on Boom 1
Press Enter
When the Dog Bone calibration is done, the
Boom 1 sensor temporarily mounted on the
bucket can be attached again on Boom 1.
How to Take Points for Dog Bone calibration:
•
With the bucket in the first position, press over Take Point, and
wait for the position to register. When done, the point counter on the
right will advance and you will hear a beep.
•
Proceed to point 2 and take the second point.
•
Take a minimum of 10 points, rotating the bucket from completely
open to completely closed.
•
Do this with 2 different dipper stick positions.
Don‘t press enter too fast after you‘ve moved your bucket to the next
position. The bucket or the dipper stick should not swing or vibrate
while you press the enter button.
Enter